Subject Keyword Abstract Author
 
 
Parametric Study on Performance of Inertance Pulse Tube Cryocooler

K.H. Lee/J. Rhee/J.S. Kim
International Journal of Aeronautical and Space Sicences, vol. 15, no. 2, pp.205-211, 2014

Abstract : The design parameters to affect the cooling capacity of a cryocooler were examined with the application of numerical modeling to optimize an inertance pulse tube cryocooler. This modeling includes the regenerator, pulse tube, inertance tube, gas reservoir, and heat exchangers. One-dimensional modeling on strings of acoustic and thermoacoustic elements was applied to compare the design parameters. The diameter and length of the pulse tube can significantly affect the cooling capacity and efficiency. The aftercooler was optimized by maintaining a certain size. The efficiency also improved as the length of inertance tube and volume of gas reservoir are increased. It was confirmed that effective design parameters are critical to the performance of an inertance pulse tube cryocooler considering the comparison of the dimensions of each part to optimize its cooling power and efficiency.

Keyword : Inertance tube, Pulse tube cryocooler, Wave equation, Regenerator

 
 
   
The Korean Society for Aeronautical & Space Sciences
#635-4, YEOGSAM-DONG, KANGNAM-KU, SEOUL 135-703, KOREA
Tel.: +82-2-552-4795  Fax.: +82-2-552-4796  E-mail: jass@ksass.or.kr